Hydrometers Operation and Maintenance Manual7
Specications, Cont.
NETAFIM USA HYDROMETERS WITH ELECTRICAL OUTPUT
Netam USA Hydrometers are equipped with electrical output devices that combine the high reliability
of hermetically sealed, magnetically driven registers with a wide variety of electrical output options.
Hydrometers (measuring instruments) provide electrical output information about the ow of water.
When more than just the traditional register is needed, they also provide the solution for automation and
communication with controllers, electronic devices and other water delivery systems.
Netam USA has three types of transducer outputs available which provide three levels of resolution:
Reed Switch (RS) Register - low frequency pulse output for functions related
primarily to recording volume.
Photo Diode (PD) Register - standard frequency pulse output (open collector) for
functions such as rate of ow and recording total volume.
Photo Diode (PDH) Register - high frequency pulse (open collector) for functions
such as rate of ow and recording total volume.
ELECTRICAL OUTPUT SPECIFICATIONS
REED SWITCH (RS) REGISTER
The ow rate is transmitted as periodic electrical pulses are measured by the magnetic pointer in
the dial face. The hydrometer is congured to transmit a pulse according to a pre-dened volume
interval. The following summarizes the available volume intervals for various hydrometer sizes in
either gallons or cubic meters.
A three pointer register, with a magnet installed on one of the pointers.
Output denition: Volume Output
Output type: RS – Reed Switch and PD – Photo Diode
The sensor is installed in a transparent plastic cover that can be mounted on the register in one of
three positions with the pointer facing the magnet. Three values of electrical output are available
in 1:10:100 ratios.
Manufacturer
Recommended
Register Type
Recommended Register
Transducer Outputs
Baseline Basestation PDH
Hunter ACC 2-Wire PDH
Rain Bird MDC & Maxi RS
Signature All Models RS
Toro
Sentinel PDH
TDC 2-Wire PDH
Rainmaster All Models
RS (1” to 4”)
PD (6”, 8”)
Tucor
Flowmaster
PDH
& RK Series
Motorola All Models RS