1-866-294-5847 Rev 11.1.2012 www.baselinesystems.com
(Netafim or Similar Three-Wire Water Meters)
Diagram B: Flow Devices with Three Wires
BL5308FlowbiCoder
TwoWire
Connectthebluewireto
theyellowpowerwire
Connecttheyellowwire
tothesensorwire
ThreeWireFlowSensor
For Most Netafim Hydrometers (including Baseline BL-BHM series hydrometers): Connect the bare copper wire, which
is the common, to the white wire with the black stripe from the BL-5308. Connect the clear wire, which is the sensor
wire, to the yellow wire from the BL-5308. Connect the yellow wire, which is the power wire, to the blue wire from the
BL-5308.
Connectthewhitewire
withtheblackstripeto
thecommonwire
BL5308FlowbiCoderWireKey
Bluewire=power
Yellowwire=sensor
Whitewirewithblackstripe=common