Part Number: LUM0024ABRevision: ALast Updated: 12/7/2011FGR2-PE Wireless Data TransceiverFirmware 2.22U ser Manual and Reference GuideFor use with Bas
Programming Point-To-Point Extended Call Book to Use Three or Four Repeaters 66Programming Point-to-MultiPoint Call Book 67Programming Point-to-MultiP
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AVSWR Alarm EnableWeb Parameter: Reflected Power Enable check box in the SNMPTrap Limits section of the
LUM0024AB Rev AChapter 8: Viewing Transceiver Statusand StatisticsA Plus-style transceiver's status and statistics are available on the Status pa
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ARefreshing and Resetting StatisticsTo refresh the contents of the Status page automatically, select the
User Manual and Reference GuideLUM0024AB Rev AdBm or more. Noise levels significantly higher than this are an indication of a high level of interferen
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ASignalThe received signal level at this transceiver. The signal source is the transceiver that transmit
User Manual and Reference GuideLUM0024AB Rev Al On the Gateway, this statistic shows a packet that is addressed to a device the Gateway believesis on
LUM0024AB Rev A 90
LUM0024AB Rev AChapter 9: Data Communication Link ExamplesA FreeWave transceivers’ versatility allows data communication links to be established using
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AThe example below shows a configuration where a Gateway routinely calls a number of Endpoints at differ
User Manual and Reference GuideLUM0024AB Rev AThe last example is a Point-to-MultiPoint network which uses one of the sites as an Endpoint/Repeater. T
Signal Alarm Below 82Signal Alarm Enable 83Tx Rate Alarm Below 83Tx Rate Alarm Enable 83VSWR Alarm Above 83VSWR Alarm Enable 84Voltage Alarm Above 84V
LUM0024AB Rev A 94
LUM0024AB Rev AChapter 10: Additional TransceiverInformationThis chapter contains additional information about the transceivers described in this manu
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AThere is no provision for handshaking in any of the above modes of operation, so data rates of 57.6 KBa
User Manual and Reference GuideLUM0024AB Rev APin Assignment Signal Definition1 DSR Data Set Ready Output Always high when the radio is powered from t
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev APin Assignment Signal Definition7 RTS Request to Send Input The transceiver does not recognize RTS for
User Manual and Reference GuideLUM0024AB Rev AFGR2-PE SpecificationsSpecificationFrequency Range 902 to 928 MHz (FHSS)TransmitterOutput Power 5 mW to
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ASpecificationOperating Temperature -40° C to +75° C (-40° F to +167° F)Dimensions 6.8 in L x 3.8 in W x
User Manual and Reference GuideLUM0024AB Rev AFactory Default SettingsThe Plus-style transceivers ship from the factory with the following default set
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AParameter Default SettingDefault Gateway 192.168.111.1Web Page Port 80Spanning Tree DisabledMode Disabl
User Manual and Reference GuideLUM0024AB Rev AParameter Default SettingRepeaters DisabledSubnet ID (RX) FSubnet ID (TX) FSecurity ParameterEnable RADI
TX Success Rate 88TX Throughput 88Un-Acked Packets 88Upstream Noise 89Upstream Signal 89Uptime 89Voltage 89Wireless Version 89Chapter 9: Data Communic
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AParameter Default SettingSignal Alarm Below: -90Noise Alarm Above: -100RMS ParameterMode DisabledPaired
User Manual and Reference GuideLUM0024AB Rev AParameter Default SettingLevel 2: No AccessLevel 3: No AccessTools ParameterSite Name BlankSite Contact
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AMechanical Drawing106
LUM0024AB Rev AAppendix A: Firmware UpdatesAs of this document's release, the following firmware has been released for the model numbers to which
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AFreeWave now supports only the following versions:l SSLv3 256 bits AES256-SHAl SSLv3 128 bits AES128-SH
User Manual and Reference GuideLUM0024AB Rev Al Ack packet optimizations.l Connect/Disconnect with data.l Changed VLAN operation.l Added RMS page and
LUM0024AB Rev A 110
LUM0024AB Rev AAppendix B: Using the FreeWave TFTP ServerTFTP Server enables the transfer of the files from your computer to the Plus-style transceive
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AInstalling and Running the TFTP SeverNote: FreeWave TFTP Server requires WIndows 98/2000/XP with Micros
User Manual and Reference GuideLUM0024AB Rev ATFTP Control OptionsThe buttons at the top of the TFTP Server window control the server.Button Descripti
Deleting Transceivers from the Discovery Server List 116Changing Basic Settings Using Discovery Server 116Accessing a Transceiver's Web Page from
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AClearing the TFTP Server FileThe log file is not erased when the program is restarted and continues to
LUM0024AB Rev AAppendix C: Using the Discovery ServerYou can use the FreeWave Discovery Server to determine and set a transceiver's IP address an
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ANote: Depending on your IT department’s policies, broadcasts may be blockedthrough any routers, so the
User Manual and Reference GuideLUM0024AB Rev AIf the password is correct, the radio reboots and applies the requested changes. Otherwise, theradio ign
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev Al Upstream Marginl % Rxl % Txl VSWR (Reflected Power),l Templ unAcked Packetsl Distancel # Disconnectsl
User Manual and Reference GuideLUM0024AB Rev A3. Name the file and click Save.The file is saved with a .pnf extensionTo import a network file:1. Open
LUM0024AB Rev A 120
LUM0024AB Rev AAppendix D: Changing the Computer IPAddress in WindowsThe following sections detail how to change the IPaddress of your computer in Wi
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A5. Select the Use the following IP address radio button, and enter an appropriate IP address in theIP A
User Manual and Reference GuideLUM0024AB Rev A5. Click Properties to display the Local Area Connection Properties window.6. Select Internet Protocol V
LUM0024AB Rev A xiv
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A9. Click OK to accept your changes and OK again to close the Local Area Connection Propertieswindow.124
LUM0024AB Rev AAppendix E: Object Tree for FREEWAVE-TECHNOLOGIES-MIBThis appendix includes a visual representation of the FREEWAVE-TECHNOLOGIES-MIB fi
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A 126
User Manual and Reference GuideLUM0024AB Rev A(continued)127
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AObject List for FREEWAVE-TECHNOLOGIES-MIBObject Description Access SyntaxfwtPlusModemIndex An index use
User Manual and Reference GuideLUM0024AB Rev AObject Description Access SyntaxfwtPlusModemPacketRxCount The Number of ethernet packets the radiohas re
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AObject Description Access SyntaxfwtPlusModemRxSubnetID A numerical ID that radios use to decidewhich su
User Manual and Reference GuideLUM0024AB Rev AGroup Object Description ObjectsfwtPlusModemReflectedPowerBad This notification is generatedwhen the ref
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AGroup Object Description ObjectsfwtPlusModemStatusGroup A collection of objectsconcerned with the curre
User Manual and Reference GuideLUM0024AB Rev AGroup Object Description ObjectsfwtPlusModemControlGroup A collection of objectsconcerned with the curre
LUM0024AB Rev APrefaceThis document includes the following regarding your FreeWave FGR2-PE transceiver:l An introduction to the transceiver, its ports
LUM0024AB Rev A 134
IndexAAddressed Repeat, defined 52AES Encryption Key, defined 72Alarm IP & Port, defined 42Alarm Retry Limit, defined 43alarmsattempts 43enabling
diagnosticsin Discovery Server 117per frequency 85viewing 85Disconnect Count, defined 86Discovery Serverabout 115adding transceivers 116deleting trans
IP Address 32NTP Client Enable 33NTP Client IP Address 33Push to Syslog Server 33Spanning Tree 33Subnet Mask 34Syslog Server 1 34Syslog Server 2 34VLA
Packets Sent, defined 87parameter referenceAddressed Repeat 52AES Encryption Key 72Alarm IP & Port 42Alarm Retry Limit 43Auth Method 78Auth Passwo
TCP Client Enable 46TCP Client IP 47TCP Client Port 47TCP Server Enable 47TCP Server Port 48Transmit Power 65Transmit Rate 65Trap Community 79Trap Man
RF Data Rate 61Slave Attempts 61Slave Connect Odds 62Subnet ID 62Transmit Power 65Transmit Rate 65RADIUS Enable, defined 74RADIUS IP Address, defined
TCP Server Port 48UDP Des. IP & Port 48-49UDP Local IP Port 48UDP Power Up IP 48UDP Power Up Port 49UDP/Multicast Enable 49Utilize For Alarm 50Sha
Temperature 88TX Success Rate 88TX Throughput 88Un-Acked Packets 88upstream connections 86Upstream Noise 89Upstream Signal 89Uptime 89Voltage 89Wirele
deleting 23Group Levels 22logins 22passwords 24Utilize For Alarm, defined 50VVLAN Configuration parametersData ID 35Default Gateway 35IP Address 35Man
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AThe term "radio" and "transceiver" are used throughout this manual to refer to the
LUM0024AB Rev AChapter 1: IntroductionThe FGR2-PE offers industrial serial and Ethernet wireless connectivity using the license-free spreadspectrum fo
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AThis port is currently non-functioning. No settings and no diagnostics are delivered to this port. AllP
User Manual and Reference GuideLUM0024AB Rev AStatus 10 BaseT Link/Activity 100 Baste T Link LEDLinked, data activityBlinking/Flickering green Solid g
Safety InformationThe products described in this manual can fail in a variety of modes due to misuse, age, or malfunction. Systemswith these products
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev Ato the Gateway. In a MultiPoint network, you determine the set number of times outbound packets from th
User Manual and Reference GuideLUM0024AB Rev APoint-to-MultiPoint Operation LEDsGateway Endpoint RepeaterConditionCarrierDetect(CD)Transmit(Tx)Clear t
LUM0024AB Rev A 6
LUM0024AB Rev AChapter 2: Setting Up andProgramming TransceiversThis chapter provides details about setting up, programming, and defining who has acce
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AIf using Tool Suite, ensure that the computer running Tool Suite has an IPaddress whose firstthree oct
User Manual and Reference GuideLUM0024AB Rev ADetermining and Setting a Transceiver's IP AddressBefore you can work with a Plus-style transceiver
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A3. In the Name field, enter a descriptive name for the connection and select an icon from the Iconselec
User Manual and Reference GuideLUM0024AB Rev AEnter the following port settings for a proper connection:Port Setting SelectBits per second 19200Data b
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AImportant: To make changes to the connection properties, you must first disconnectthe terminal session.
User Manual and Reference GuideLUM0024AB Rev A4. Enter 0 to select the IP Setup Menu to display the IPAddress along with the other IP setupoptions:Th
This product is licensed by The United States. Diversion contrary to U.S. law is prohibited. Shipment or re-export of this product outside of The Unit
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AUsing Discovery ServerYou can also determine and a set the IP address of a Plus-style transceiver with
User Manual and Reference GuideLUM0024AB Rev A3. In the IP Address field, update the IPaddress to the address you want to assign to thetransceiver.4.
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A4. Enter default at the prompt and pressEnter.The transceiver reboots, and all of the transceiver sett
User Manual and Reference GuideLUM0024AB Rev AEach page or tab contains parameters that apply to the same area of functionality. For example, to setup
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev APage Used ToRMS Set FreeWave Redundant Master System units only. For details aboutthese settings, see t
User Manual and Reference GuideLUM0024AB Rev AAccessing Configuration Web PagesEach Plus-style transceiver has a built in Web interface that you can u
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AAny change made in the configuration Web pages that is not yetsaved is highlighted in yellow. This high
User Manual and Reference GuideLUM0024AB Rev A2. In the Pages menu on the left side, click Tools to display the Tools page.3. In the Change Site Infor
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AImportant: Changes made to the settings on this page can cause the radios to losecommunication with the
User Manual and Reference GuideLUM0024AB Rev ANote: You cannot change the group assigned to the admin user. The admin useralways has Full Access to al
FCC NotificationsThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) Thisdevice may not cause
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A5.Click Add User to create the user account, or click the red icon in the upper right corner of thedial
User Manual and Reference GuideLUM0024AB Rev AWarning! Downgrading an Plus-style transceiver from the current firmware version toa previous firmware v
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A4. Click OK and verify that the folder is listed in the Root Folder field.5. Click OK to return to the
User Manual and Reference GuideLUM0024AB Rev AIf the firmware file is being uploaded to the transceiver, there is a new entry in the FreeWave TFTPServ
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A2. In the Pages menu on the left side, click Tools to display the Tools page.3. In the Address of TFTP
User Manual and Reference GuideLUM0024AB Rev A5. Scroll until you see Hide extensions for known file types and deselect the box next to thisoption.6.
LUM0024AB Rev A 30
LUM0024AB Rev AChapter 3: IP and NetworkCommunication SettingsThe parameters on the IP Setup tab or IP Setup configuration Web page are typically set
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ANetwork Type: Point-to-Point, Point-to-MultiPoint, or BothDefault Setting: The factory default setting
User Manual and Reference GuideLUM0024AB Rev ANTP Client EnableWeb Parameter Enable check box in the NTPClient section of the IP Setup page.Network T
Document RevisionHistoryDate Rev Letter Updates Made12/07/2011 A Updates include but are not limited to:l Document is now broken into chapters and a
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ANetwork Type: BothDefault Setting: DisabledOptions: Disabled, EnabledDescription: Enabling this paramet
User Manual and Reference GuideLUM0024AB Rev AVLAN Data IDWeb Page: Data VLAN ID in the VLAN Configuration (Data) section of the IP Setup page.Network
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AOptions: Any valid VLAN ID between 1 and 4095.Description: Computers and devices using the VLAN ID ente
User Manual and Reference GuideLUM0024AB Rev ADescription: Use this setting to change the assigned port for the configuration Web pages.The default se
LUM0024AB Rev A 38
LUM0024AB Rev AChapter 4: Serial Port SettingsUse the settings on the Serial Setup tab or page to set the serial ports on the transceiver. The ports a
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev A4. Select Enabled in one of the following fields to enable that mode. If all the fields are set toDisab
User Manual and Reference GuideLUM0024AB Rev Al TCP Server Enablel TCP Client Enablel UDP/Multicast Enable5. Select a Tool Suite program option to sen
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AEthernet (Rx and Tx)The amount of data received (rx) and transmitted (tx) from the terminal server to t
User Manual and Reference GuideLUM0024AB Rev AAlarm Retry Limit (Attempts)Web Parameter: Alarm Retry Limit in the TCP Server Settings of the Serial Se
LUM0024AB Rev A vi
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AIn the configuration Web pages, enter the IP address in the field to the left ofthe colon. Enter the po
User Manual and Reference GuideLUM0024AB Rev Atransmission of data.Description: Controls the function of the CD line on the serial port.Serial Data Bi
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ASetting this option is recommended for any serial data that consist of manysmall packets of data.Serial
User Manual and Reference GuideLUM0024AB Rev ATCP Client IPWeb Parameter IPAddress & Port in the TCPClient Settings section of the Serial Setupp
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AOptions: Any number of seconds.Description: Controls how long, in seconds, an incoming TCP connection m
User Manual and Reference GuideLUM0024AB Rev AUDP Power Up PortWeb Parameter Power UP Dest. IP & Port in the UDPSettings section of the SerialSe
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AIn a MultiPoint Gateway radio, selecting multicast causes the transceiver to act asan IP Multicast Send
LUM0024AB Rev AChapter 5: Radio SettingsUse the settings on the Radio Setup tab or Radio Setup configuration Web page to set the general functioningof
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ARadio Setup Parameter ReferenceThis section contains the following information as it applies to the rad
User Manual and Reference GuideLUM0024AB Rev ANetwork Type: MultiPointDefault Setting: 3Options: Any number between 0 and 9.Description: In a MultiPoi
Table Of ContentsChapter 1: Introduction 1Getting to Know Your Plus-Style Transceiver 1Boot-Up LED Sequence 2Ethernet Port Conditions 2Error LED Condi
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AFrequency KeyWeb Parameter: Frequency Key in the TransmissionCharacteristics section of the RadioSetup
User Manual and Reference GuideLUM0024AB Rev ADefault Setting: 255Options: Any number between 0 and 4095.Description: Use the Network ID to establish
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AOptions: Any number between 0 and 9.Description: The Max and Min Packet Size settings and the RF Data R
User Manual and Reference GuideLUM0024AB Rev AMaximum Packet Size Definition with RFData Rate of 154 kbps (in bytes)Max Setting (blank area = not rec
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AMaximum Packet Size Definition with RF Data Rate of 864 kbps (in bytes)Max Setting (blank area = not re
User Manual and Reference GuideLUM0024AB Rev AOperation Mode DescriptionPoint-to-Point Endpoint Designates the transceiver as an Endpoint in Point-to-
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ADescription: Indicates the type of network the transceiver resides in. This selection and theselection
User Manual and Reference GuideLUM0024AB Rev Aroving Gateway or Endpoint(s). As the link gets weaker, a lower setting allowsa poor link to break in se
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev Ahigher the Slave Connect Odds setting, the more persistent that Endpointwill be in attempting to acquir
User Manual and Reference GuideLUM0024AB Rev AF, an Endpoint or Repeater connects with the first Repeater or Gateway that ithears with the same Networ
IP Parameter Reference 31Default Gateway 32IP Address 32NTP Client Enable 33NTP IP Address 33Push to Syslog Server 33Spanning Tree 33Subnet Mask 34Sys
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AThe following table shows the subnet IDs for the above example:TransceiverSubnetID(RX)SubnetID (TX) Oth
User Manual and Reference GuideLUM0024AB Rev ATransmit PowerWeb Parameter: Transmit Power in the Transmission Characteristics section of theRadioSetu
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AAbout the Call BookThe Call Book is required in Point-to-Point networks. While the Call Book is an opti
User Manual and Reference GuideLUM0024AB Rev ATo call an Endpoint through one or more Repeaters, that Endpoint must be called individually. With Call
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ANumber(0) 884-1111(1) 884-2222(2) 000-0000At times, you may want to force an Endpoint to go through a s
User Manual and Reference GuideLUM0024AB Rev ATo set the Call Book in HyperTerminal:1. Select (2) Call Book from the main Setup menu to display the fo
LUM0024AB Rev A 70
LUM0024AB Rev AChapter 6: Security SettingsUse the settings on the Security tab or Security configuration Web page to define elements that furtherenha
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev Aeach time a firmware upgrade is initiated, the system makes an entry in the log.The system log time is
User Manual and Reference GuideLUM0024AB Rev AOptions: Any free form text up to 16 characters long.Description: A user-defined encryption key for the
Serial Modbus RTU 45Serial Parity 46Stop Bits 46TCP Client Enable 46TCP Client IP 47TCP Client Port 47TCP Server Enable 47TCPServer Inactivity Timeou
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AEntering a hardware (MAC) address in the MAC Filter field and clicking Addputs that MAC address into th
User Manual and Reference GuideLUM0024AB Rev Aneither sent via the Ethernet port, nor via the radio link.RADIUS IP AddressNote: This option is control
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ASecurity page.Network Type: BothDefault Setting: BlankOptions: Any free form text.Description: The RADI
LUM0024AB Rev AChapter 7: SNMP SettingsUse the simple network management protocol (SNMP) settings located in the SNMP tab or page to helpmonitor the s
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AOptions: The options to which the parameter can be set.Description: A description of what the parameter
User Manual and Reference GuideLUM0024AB Rev APrivacy Password (v3)Note: This option is only available when v3 is selected as the SNMP Version.Web Par
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev ATrap Manager IPWeb Parameter: Trap Manager 1 IP and Trap Manager 2 IP in the SNMPTrap Configurationsec
User Manual and Reference GuideLUM0024AB Rev Ayour network.The parameters are listed in alphabetical order by their Tool Suite field name.Delta Alarm
FGR2-PE Wirelss Data TransceiverLUM0024AB Rev AOptions: Any whole, negative number between -100 and -70 db, in increments of 5.Description: If the Noi
User Manual and Reference GuideLUM0024AB Rev ASignal Alarm EnableWeb Parameter: Signal Enable check box in the SNMPTrap Limits section of the SNMPpag
Comentarios a estos manuales