Page | 97
Graph Not Moving
Characteristics
The graph shows only a little movement and the ground where the
sensor is located is saturated.
The overall trend of the graph may be flat but there are sharp peaks that
correspond to the watering cycles. The peaks fall off rapidly.
Recommendation
The ground is near, at, or above field capacity and does not dry out
between watering days.
Check the watering frequency. If the system is watering daily or every
two days, increase the days between watering.
Click the Too Wet button in the Set Sensor section of the Adjustment
and Centering group box below the graph.
If the problem persists, the sensor may be too deep. It should not be buried any deeper than 4 inches and typically, 2 3
inches is an adequate depth for most sensors.