Sample Wiring Topologies
Figure 1 Straight Run
Figure 2 Star
Figure 3 Combination Topology
Figure 4 Complete Loop
Wiring Hints
For wiring specifications, refer to the Two-Wire Tech Spec on Baselines web site (www.baselinesystems.com). Use the
appropriate wire type for your project. Typical PVC irrigation wire, without a second layer of insulation is not suitable. If you use
an unspecified wire type, it will void your warranty. Make sure your backbone wire and field wires are two different colors.
Wiring Connections
Use wire connections that are DBR/Y-6 or equivalent on the two-wire side and on the valve side. Install all connections
according to their manufacturer’s instructions.
Note: Two-wire systems have constant power running through them. If a connection is not waterproof or has any contact with
earth, the connections will quickly corrode. Your warranty will be voided if you fail to use the wire connections as described in
the specification.