Baseline-systems BHM Series Hydrometer Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
24Hydrometers Operation and Maintenance Manual
Maintenance 1½” - 8” Hydrometers
HYDROMETER REMOVAL FROM PIPELINE
The hydrometer is designed for easy site repairs. Removal from the pipeline is not required for
dis-assembly and most repairs. The following removal instructions are included
in the unlikely event that the hydrometer needs to be disassembled and repaired in the shop.
1½” and 2” Models
The 1½” model may only be attached, using a coupling, to a male threaded pipeline.
Coupling Connection
Unscrew the coupling nuts on both sides of the hydrometer counterclockwise.
Slide the coupling nuts away from the hydrometer and remove the hydrometer from the
pipeline. Retain the coupling gaskets.
Direct Connection
If the hydrometer is attached directly to the pipeline, unscrew the pipeline on both sides of the
hydrometer.
Remove the hydrometer from the pipeline.
3” - 8” Models
Unscrew and remove the bolts from the anged connections on both sides of the hydrometer.
Remove the hydrometer from the pipeline.
Inspect the gaskets and replace as necessary.