Baseline-systems BHM Series Hydrometer Manual de usuario Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
Hydrometers Operation and Maintenance Manual33
Maintenance 6” Models, Cont.
DIAPHRAGM AND UPPER STEM BEARING
Dis-assembly
Unscrew and remove the 12 screws (17) and remove the upper
diaphragm ring (18).
Remove the diaphragm (19).
Inspect for cracks or excessive wear and replace as necessary.
Inspect the upper stem wiper (20) and replace as necessary.
Remove the upper stem bearing (21) from inside the stem
(24). Inspect the upper stem bearing (21) along with the upper
stem bearing o-ring (22) and the stem o-ring (15). Replace as
necessary.
Re-assembly
Replace the upper stem wiper (20) onto the upper stem bearing
(21)
Replace the upper stem bearing (21) into the stem (24).
Place the diaphragm (19) into the grooves on the stem (24).
Place the upper diaphragm ring (18) over the diaphragm and
screw the 12 stem screws (17) into place.
LOWER STEM BEARING AND VALVE COVER
Dis-assembly
Unscrew and remove the stem lock nut (29).
Pull the valve cover (28) from the stem. Inspect the rubber for
cracks or excessive wear. Replace as necessary.
Inspect the lower valve cover o-ring (26) and replace as
necessary. It is located in a groove inside the valve cover
opening.
Using a screwdriver, remove the lock ring (27) from inside the
bottom of the stem (24).
Inspect the lower stem bearing wiper (20) and the lower stem
bearing o-ring (22) and replace as necessary.
Inspect and replace the lower stem bearing (25) as necessary.
Use a pipe wrench to remove it from the stem (24).
Apply Loctite 270 or similar glue to the threads of the lower
stem bearing (25).
Screw it back into the stem (24).
Re-assembly
Replace the lower stem wiper (20) into the bottom of the stem
(24).
Snap the wiper locking ring (27) into the stem (24).
Push the valve cover (28) onto the lower stem bearing (25).
Apply Loctite 270 or similar glue to the threads of the stem
lock nut (29).
Screw the stem lock nut (29) into the stem (24). Do not over
tighten. Make sure that the valve cover is free to move up and
down slightly.